Brand Name: | Rexroth |
Model Number: | 4WE6J6X/EW110N9DAL/B08V (R900910382) |
MOQ: | 1 |
Price: | $418 |
Payment Terms: | T/T, |
Size | 6 | ||
Weight | Valve with one solenoid | kg | 1.45 |
Valve with two solenoids | kg | 1.95 | |
Installation position | any | ||
Ambient temperature range | NBR seals | °C | -20 … +50 |
FKM seals | °C | -15 … +50 | |
Version for HFC hydraulic fluid | °C | -20 … +50 | |
Low-temperature version 1) | °C | -40 … +50 | |
Storage temperature range | °C | +5 … +40 | |
MTTFD values according to EN ISO 13849 2) | Years | 300 |
1) | For the use at low temperatures, see Project planning information |
2) | For further details, see data sheet 08012 |
Size | 6 | |||
Maximum operating pressure | Port P | Standard version | bar | 350 |
Version "SO407" | bar | 315 | ||
Port A | Standard version | bar | 350 | |
Version "SO407" | bar | 315 | ||
Port B | Standard version | bar | 350 | |
Version "SO407" | bar | 315 | ||
Port T | Direct voltage 1) | bar | 210 | |
AC voltage 1) | bar | 160 | ||
Maximum flow | Direct voltage | Standard version | l/min | 80 |
Version "SO407" | l/min | 60 | ||
AC voltage | l/min | 60 | ||
Flow cross-section (spool position 0) | Symbol Q | approx. 6 % of nominal cross-section | ||
Symbol W | approx. 3 % of nominal cross-section | |||
Hydraulic fluid | see table "Hydraulic fluid" | |||
Hydraulic fluid temperature range | NBR seals | °C | -20 … +80 | |
FKM seals | °C | -15 … +80 | ||
Version for HFC hydraulic fluid | °C | -20 … +50 | ||
Low-temperature version 2) | °C | -40 … +50 | ||
Viscosity range | mm²/s | 2.8 … 500 | ||
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 3) | Class 20/18/15 |
1) | With symbols A and B, port T must be used as leakage oil connection if the operating pressure exceeds the admissible tank pressure. |
2) | For the use at low temperatures, see Project planning information |
3) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
Hydraulic fluid | Classification | Suitable sealing materials | Standards | Data sheet | |
Mineral oils | HL, HLP, HLPD, HVLP, HVLPD | NBR, FKM | DIN 51524 | 90220 | |
Bio-degradable | Insoluble in water | HETG | FKM | ISO 15380 | 90221 |
HEES | FKM | ||||
Soluble in water | HEPG | FKM | ISO 15380 | ||
Flame-resistant | Water-free | HFDU (glycol base) | FKM | ISO 12922 | 90222 |
HFDU (ester base) | FKM | ||||
HFDR | FKM | ||||
Containing water | HFC (Fuchs: Hydrotherm 46M, Renosafe 500; Petrofer: Ultra Safe 620; Houghton: Safe 620; Union: Carbide HP5046) |
NBR | ISO 12922 | 90223 | |
Important information on hydraulic fluids: |
Voltage type | Direct voltage | AC voltage 50/60 Hz | Direct voltage | AC voltage 50/60 Hz | |||
Nominal voltage according to VDE 0580 | See "Type codes" | ||||||
Voltage tolerance (nominal voltage) | % | ± 10 | |||||
Nominal power according to VDE 0580 | Standard version | W | 30 | - | 30 | - | |
Version "SO407" | W | 8 | - | 8 | - | ||
Version "= UR" | W | 34 | - | 34 | - | ||
Holding power | VA | - | 50 | - | 50 | ||
Switch-on power | VA | - | 220 | - | 220 | ||
Duty cycle | 100% (S1 according to VDE 0580) | ||||||
Switching time according to ISO 6403 1) | ON | ms | 25 … 45 | 10 … 20 | 25 … 45 | 10 … 20 | |
OFF | ms | 10 … 25 | 15 … 40 | 10 … 25 | 15 … 40 | ||
Maximum switching frequency | Standard version | 1/s | 4.2 | 2 | 4.2 | 2 | |
Version "SO407" | 1/s | 2 | - | 2 | - | ||
Maximum surface temperature of the coil 2) | Standard version | °C | 120 | 180 | 120 | 180 | |
Version "SO407" | °C | 85 | - | 85 | - | ||
Version "= UR" | °C | 120 | - | 120 | - | ||
Insulation class VDE 0580 | Standard | F | H | F | H | ||
Version "= UR" | Version "G12", "G24" | F | |||||
Version "G110", "W120R" | H | ||||||
Protection class according to DIN EN 60529 | See "Type codes" | ||||||
Protection class according to VDE 0580 | See "Type codes" | ||||||
Electrical fuse protection | Maximum admissible switch-off overvoltage see "Type codes". Every solenoid must be protected individually, using a suitable fuse with tripping characteristics K (inductive loads). |
||||||
Protective earthing conductor and screening | The valve must be installed on a surface that is included in the equipotential bonding. Connector pin assignment (CE-compliant installation) see "Electrical connection". |
||||||
Conformity | CE according to Low-Voltage Directive 2014/35/EU checked according to EN 60204-1:2006-01 and DIN VDE 0580, classified as component. |
1) | Measured without flow. The switching times were determined for a hydraulic fluid temperature of 40 °C and a viscosity of 46 mm2/s. Switching times change dependent on hydraulic fluid temperatures, operating time and application conditions. |
2) | Due to the temperatures occurring at the surfaces of the solenoid coils, the standards ISO 13732-1 and ISO 4413 need to be adhered to!The specified surface temperature in AC solenoids is valid for fault-free operation. In the error case (e.g. blocking of the control spool), the surface temperature may increase above 180 °C. Thus, the system must be checked for possible dangers considering the ignition temperature of the hydraulic fluid used. As fuse protection, circuit breakers must be used, unless the creation of an ignitable atmosphere can be excluded in a different way. In this way, the surface temperature in an error case can be limited to a maximum of 220 °C. You have to use cables that have been approved of for a working temperature of more than 50 °C (individual connection) and/or 90 °C (central connection). |
![]() |
Brand Name: | Rexroth |
Model Number: | 4WE6J6X/EW110N9DAL/B08V (R900910382) |
MOQ: | 1 |
Price: | $418 |
Payment Terms: | T/T, |
Size | 6 | ||
Weight | Valve with one solenoid | kg | 1.45 |
Valve with two solenoids | kg | 1.95 | |
Installation position | any | ||
Ambient temperature range | NBR seals | °C | -20 … +50 |
FKM seals | °C | -15 … +50 | |
Version for HFC hydraulic fluid | °C | -20 … +50 | |
Low-temperature version 1) | °C | -40 … +50 | |
Storage temperature range | °C | +5 … +40 | |
MTTFD values according to EN ISO 13849 2) | Years | 300 |
1) | For the use at low temperatures, see Project planning information |
2) | For further details, see data sheet 08012 |
Size | 6 | |||
Maximum operating pressure | Port P | Standard version | bar | 350 |
Version "SO407" | bar | 315 | ||
Port A | Standard version | bar | 350 | |
Version "SO407" | bar | 315 | ||
Port B | Standard version | bar | 350 | |
Version "SO407" | bar | 315 | ||
Port T | Direct voltage 1) | bar | 210 | |
AC voltage 1) | bar | 160 | ||
Maximum flow | Direct voltage | Standard version | l/min | 80 |
Version "SO407" | l/min | 60 | ||
AC voltage | l/min | 60 | ||
Flow cross-section (spool position 0) | Symbol Q | approx. 6 % of nominal cross-section | ||
Symbol W | approx. 3 % of nominal cross-section | |||
Hydraulic fluid | see table "Hydraulic fluid" | |||
Hydraulic fluid temperature range | NBR seals | °C | -20 … +80 | |
FKM seals | °C | -15 … +80 | ||
Version for HFC hydraulic fluid | °C | -20 … +50 | ||
Low-temperature version 2) | °C | -40 … +50 | ||
Viscosity range | mm²/s | 2.8 … 500 | ||
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 3) | Class 20/18/15 |
1) | With symbols A and B, port T must be used as leakage oil connection if the operating pressure exceeds the admissible tank pressure. |
2) | For the use at low temperatures, see Project planning information |
3) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
Hydraulic fluid | Classification | Suitable sealing materials | Standards | Data sheet | |
Mineral oils | HL, HLP, HLPD, HVLP, HVLPD | NBR, FKM | DIN 51524 | 90220 | |
Bio-degradable | Insoluble in water | HETG | FKM | ISO 15380 | 90221 |
HEES | FKM | ||||
Soluble in water | HEPG | FKM | ISO 15380 | ||
Flame-resistant | Water-free | HFDU (glycol base) | FKM | ISO 12922 | 90222 |
HFDU (ester base) | FKM | ||||
HFDR | FKM | ||||
Containing water | HFC (Fuchs: Hydrotherm 46M, Renosafe 500; Petrofer: Ultra Safe 620; Houghton: Safe 620; Union: Carbide HP5046) |
NBR | ISO 12922 | 90223 | |
Important information on hydraulic fluids: |
Voltage type | Direct voltage | AC voltage 50/60 Hz | Direct voltage | AC voltage 50/60 Hz | |||
Nominal voltage according to VDE 0580 | See "Type codes" | ||||||
Voltage tolerance (nominal voltage) | % | ± 10 | |||||
Nominal power according to VDE 0580 | Standard version | W | 30 | - | 30 | - | |
Version "SO407" | W | 8 | - | 8 | - | ||
Version "= UR" | W | 34 | - | 34 | - | ||
Holding power | VA | - | 50 | - | 50 | ||
Switch-on power | VA | - | 220 | - | 220 | ||
Duty cycle | 100% (S1 according to VDE 0580) | ||||||
Switching time according to ISO 6403 1) | ON | ms | 25 … 45 | 10 … 20 | 25 … 45 | 10 … 20 | |
OFF | ms | 10 … 25 | 15 … 40 | 10 … 25 | 15 … 40 | ||
Maximum switching frequency | Standard version | 1/s | 4.2 | 2 | 4.2 | 2 | |
Version "SO407" | 1/s | 2 | - | 2 | - | ||
Maximum surface temperature of the coil 2) | Standard version | °C | 120 | 180 | 120 | 180 | |
Version "SO407" | °C | 85 | - | 85 | - | ||
Version "= UR" | °C | 120 | - | 120 | - | ||
Insulation class VDE 0580 | Standard | F | H | F | H | ||
Version "= UR" | Version "G12", "G24" | F | |||||
Version "G110", "W120R" | H | ||||||
Protection class according to DIN EN 60529 | See "Type codes" | ||||||
Protection class according to VDE 0580 | See "Type codes" | ||||||
Electrical fuse protection | Maximum admissible switch-off overvoltage see "Type codes". Every solenoid must be protected individually, using a suitable fuse with tripping characteristics K (inductive loads). |
||||||
Protective earthing conductor and screening | The valve must be installed on a surface that is included in the equipotential bonding. Connector pin assignment (CE-compliant installation) see "Electrical connection". |
||||||
Conformity | CE according to Low-Voltage Directive 2014/35/EU checked according to EN 60204-1:2006-01 and DIN VDE 0580, classified as component. |
1) | Measured without flow. The switching times were determined for a hydraulic fluid temperature of 40 °C and a viscosity of 46 mm2/s. Switching times change dependent on hydraulic fluid temperatures, operating time and application conditions. |
2) | Due to the temperatures occurring at the surfaces of the solenoid coils, the standards ISO 13732-1 and ISO 4413 need to be adhered to!The specified surface temperature in AC solenoids is valid for fault-free operation. In the error case (e.g. blocking of the control spool), the surface temperature may increase above 180 °C. Thus, the system must be checked for possible dangers considering the ignition temperature of the hydraulic fluid used. As fuse protection, circuit breakers must be used, unless the creation of an ignitable atmosphere can be excluded in a different way. In this way, the surface temperature in an error case can be limited to a maximum of 220 °C. You have to use cables that have been approved of for a working temperature of more than 50 °C (individual connection) and/or 90 °C (central connection). |