Brand Name: | Rexroth |
Model Number: | 4WE6J6X/EW110N9DAL/B08V (R900910382) |
MOQ: | 1 |
Price: | $418 |
Payment Terms: | T/T, |
Size | 6 | ||
Weight (approx.) | Valve with one actuation cylinder | kg | 2 |
Valve with two actuation cylinders | kg | 2.2 | |
Installation position 1) | any | ||
Ambient temperature range | NBR seals | °C | -30 … +80 |
FKM seals | °C | -20 … +80 |
1) | With version ../O.. (A, C and D) : horizontal |
Size | 6 | ||
Maximum operating pressure | Port P | bar | 315 |
Port A | bar | 315 | |
Port B | bar | 315 | |
Port T 1) | bar | 160 | |
Maximum flow | l/min | 60 | |
Flow cross-section (spool position 0) | Symbol Q | mm2 | approx. 6 % of nominal cross-section |
Symbol W | mm2 | approx. 3 % of nominal cross-section | |
Minimum pilot pressure 2) | bar | 6 | |
Maximum pilot pressure | bar | 200 | |
Pilot volume | cm³ | 1.23 | |
Hydraulic fluid | see table | ||
Hydraulic fluid temperature range | NBR seals | °C | -30 … +80 |
FKM seals | °C | -20 … +80 | |
Viscosity range | mm²/s | 2.8 … 500 | |
Maximum admissible degree of contamination of the hydraulic fluid 3) | Class 20/18/15 according to ISO 4406 (c) | ||
Maximum switching frequency | Hz | 2 |
1) | With symbols A and B, port T must be used as leakage oil connection if the operating pressure exceeds the admissible tank pressure. |
2) | 6 ... 10 bar > tank pressure, performance limits dependent on the minimum pilot pressure, see chapter "Diagrams/characteristic curves", section "Performance limits" |
3) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
Hydraulic fluid | Classification | Suitable sealing materials | Standards | |
Mineral oil | HL, HLP | FKM, NBR | DIN 51524 | |
Bio-degradable | Insoluble in water | HEES (synthetic esters) | FKM | VDMA 24568 |
HETG (rape seed oil) | FKM, NBR | |||
Soluble in water | HEPG (polyglycols) | FKM | VDMA 24568 | |
Other hydraulic fluids on request |
The electric connection is realized via a 4-pole mating connector (separate order) with connection thread M12 x 1.
Connection voltage (DC voltage) | V | 24 | ||
Voltage tolerance (connection voltage) | +30 %/-15 % | |||
Admissible residual ripple | % | ≤ 10 | ||
Max. load capacity | mA | 400 | ||
Switching outputs ![]() |
PNP transistor outputs, load between switching outputs and GND | |||
Pinout ![]() |
1 | V | 24 | |
2, 4 | Switching output | mA | 400 | |
3 | Earthing (GND) | V | 0 |
For applications outside these parameters, please consult us!
![]() |
Brand Name: | Rexroth |
Model Number: | 4WE6J6X/EW110N9DAL/B08V (R900910382) |
MOQ: | 1 |
Price: | $418 |
Payment Terms: | T/T, |
Size | 6 | ||
Weight (approx.) | Valve with one actuation cylinder | kg | 2 |
Valve with two actuation cylinders | kg | 2.2 | |
Installation position 1) | any | ||
Ambient temperature range | NBR seals | °C | -30 … +80 |
FKM seals | °C | -20 … +80 |
1) | With version ../O.. (A, C and D) : horizontal |
Size | 6 | ||
Maximum operating pressure | Port P | bar | 315 |
Port A | bar | 315 | |
Port B | bar | 315 | |
Port T 1) | bar | 160 | |
Maximum flow | l/min | 60 | |
Flow cross-section (spool position 0) | Symbol Q | mm2 | approx. 6 % of nominal cross-section |
Symbol W | mm2 | approx. 3 % of nominal cross-section | |
Minimum pilot pressure 2) | bar | 6 | |
Maximum pilot pressure | bar | 200 | |
Pilot volume | cm³ | 1.23 | |
Hydraulic fluid | see table | ||
Hydraulic fluid temperature range | NBR seals | °C | -30 … +80 |
FKM seals | °C | -20 … +80 | |
Viscosity range | mm²/s | 2.8 … 500 | |
Maximum admissible degree of contamination of the hydraulic fluid 3) | Class 20/18/15 according to ISO 4406 (c) | ||
Maximum switching frequency | Hz | 2 |
1) | With symbols A and B, port T must be used as leakage oil connection if the operating pressure exceeds the admissible tank pressure. |
2) | 6 ... 10 bar > tank pressure, performance limits dependent on the minimum pilot pressure, see chapter "Diagrams/characteristic curves", section "Performance limits" |
3) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
Hydraulic fluid | Classification | Suitable sealing materials | Standards | |
Mineral oil | HL, HLP | FKM, NBR | DIN 51524 | |
Bio-degradable | Insoluble in water | HEES (synthetic esters) | FKM | VDMA 24568 |
HETG (rape seed oil) | FKM, NBR | |||
Soluble in water | HEPG (polyglycols) | FKM | VDMA 24568 | |
Other hydraulic fluids on request |
The electric connection is realized via a 4-pole mating connector (separate order) with connection thread M12 x 1.
Connection voltage (DC voltage) | V | 24 | ||
Voltage tolerance (connection voltage) | +30 %/-15 % | |||
Admissible residual ripple | % | ≤ 10 | ||
Max. load capacity | mA | 400 | ||
Switching outputs ![]() |
PNP transistor outputs, load between switching outputs and GND | |||
Pinout ![]() |
1 | V | 24 | |
2, 4 | Switching output | mA | 400 | |
3 | Earthing (GND) | V | 0 |
For applications outside these parameters, please consult us!