Send Message
Good price online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Rexroth Hydraumatic Parts
Created with Pixso. Bosch Rexroth 4WREQ10Q5-75-2X/VBF-24CA60 Direct Operated Proportional Directional Valve

Bosch Rexroth 4WREQ10Q5-75-2X/VBF-24CA60 Direct Operated Proportional Directional Valve

Brand Name: Rexroth
Model Number: 4WREQ10Q5-75-2X/VBF-24CA60 (R901057547)
MOQ: 1
Price: $418
Payment Terms: T/T,
Detail Information
Spool Symbol:
Symbol J
Max. Pressure:
350
Electrical Connection Description:
Cable Gland, Threaded Connection 1/2"-14 NPT, With LED
Productgroup ID:
9,10,11,12,13,14
Number Of Ports:
4
Product Typ:
With Solenoid Actuation
Conformity Description:
CE – Low-Voltage Directive 2014/35/EU CSA Approval According To CSA C22.2 No. 139-1982
Size:
6
Electrical Connector:
Cable Gland
Max. Flow:
60
Connection Diagram:
NFPA T3.5.1 R2-2002 D03
Supply Voltage:
110…120 VAC
Type Of Connection:
Subplate Mounting
Seals:
FKM
Number Of Switching Positions 2:
3
Weight:
1.4
Hydraulic Fluid:
HL,HLP,HLPD,HVLP,HVLPD,HETG,HEES,HEPG,HFDU,HFDR
Supply Ability:
>100
Highlight:

Bosch Rexroth 4WREQ10Q5-75-2X

,

Proportional Directional Valve

,

Bosch Rexroth Valve 4WREQ10Q5-75-2X

Product Description

Bosch Rexroth 4WREQ10Q5-75-2X/VBF-24CA60 (R901057547) Direct Operated Proportional Directional Valve With State-Of-The-Art Integrated Digital Control Electronics Tailored For Precise Pressure

Product Description:

The Bosch Rexroth 4WREQ10Q5-75-2X/VBF-24CA60 (R901057547) is a direct operated proportional directional valve with state-of-the-art integrated digital control electronics tailored for precise pressure, force, and flow control applications. This innovative valve is designed to operate via proportional solenoids featuring a central thread and detachable coil, ensuring ease of maintenance and high responsiveness. The model includes a valve control spool that is position-controlled for accurate operation. The 4WREQ10Q5-75-2X/VBF-24CA60 valve can be equipped with an optional integrated pressure sensor plate or configured for an external pressure sensor, providing flexibility in monitoring and control based on specific application requirements. It supports subplate mounting with porting patterns according to ISO standards, ensuring compatibility with a wide range of systems. The valve's digital integrated control electronics (IACP) facilitate advanced functionalities such as error detection for cable breaks in the pressure sensor or position transducer, undervoltage issues, communication errors, and watchdog timer faults. Additional features include a ramp generator, internal command value profile, enable function for analog/digital inputs, and an error output of 24 V. Designed to communicate via field bus interfaces like CANopen protocol DS 301 or Profibus-DP, the unit allows for quick commissioning through the WINPED commissioning software. Despite its advanced capabilities, users should be aware that internal leakage is inherent to the design of these valves and may increase over their lifecycle; therefore, it's crucial to ensure that the tank line does not run empty. This Bosch Rexroth valve boasts impressive specifications with a size of 10 and a component series X. It can handle a maximum operating pressure of up to 315 bar and facilitates maximum flow rates up to 75 l/min. Its robust construction and versatile design make it suitable for various demanding hydraulic applications where precision control is critical

4WREQ 6 for external pressure sensor

Bosch Rexroth 4WREQ10Q5-75-2X/VBF-24CA60 Direct Operated Proportional Directional Valve 0

 

Features:

Direct operated proportional directional valve with integrated digital control electronics for the pressure, force and flow control (Integrated Axis Controller IAC-P) Completely adjusted unit consisting of valve, pressure sensor(s) (optional), digital control electronics and field bus connection Operation by means of proportional solenoids with central thread and detachable coil Valve control spool, position-controlled Integrated pressure sensor plate (optional) For subplate mounting: Porting pattern according to ISO 4401 Analog interface for command and actual value Design for CAN bus with CANopen protocol DS 408 or Profibus-DP Quick commissioning via PC and WIN-PED 6 commissioning software



 

Technical date :

 

general

Type 4WREQ
Size 6 10
Installation position   any, preferably horizontal
Ambient temperature range °C -20 … +50
Storage temperature range °C -20 … +80
Weight withsandwich plate (3 sensors) kg 3.6 8.5
without sandwich plate kg 2.4 6.5

hydraulic

Size 6 10
Maximum operating pressure   bar 315
Maximum operating pressure Port P (sensor 100 bar) bar 100
Port P (sensor 160 bar) bar 160
Port P (sensor 250 bar) bar 250
Port P (sensor 400 bar) bar 315
Port T (sensor 100 bar) bar 100
Port T (sensor 160 bar) bar 160
Port T (sensor 250 bar) bar 210
Port T (sensor 400 bar) bar 210
Port A (sensor 100 bar) bar 100
Port A (sensor 160 bar) bar 160
Port A (sensor 250 bar) bar 250
Port A (sensor 400 bar) bar 315
Port B (sensor 100 bar) bar 100
Port B (sensor 160 bar) bar 160
Port B (sensor 250 bar) bar 250
Port B (sensor 400 bar) bar 315
Maximum flow   l/min 80 180
Nominal flow   l/min 8
16
32
25
50
75
Hydraulic fluid     see table
Hydraulic fluid temperature range   °C -20 … +70
preferably °C +40 … +50
Viscosity range   mm²/s 20 … 380
preferably mm²/s 30 … 46
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1)   Class 20/18/15 according to ISO 4406 (c)
Hysteresis   % ≤ 0.1
Range of inversion   % ≤ 0.05
Response sensitivity   % ≤ 0.05
Zero shift upon change of Hydraulic fluid temperature %/10 K < 0.15
Operating pressure %/100 bar < 0.1
1) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.
Hydraulic fluid Classification Suitable sealing materials Standards
Mineral oils and related hydrocarbons HL, HLP NBR / FKM DIN 51524
Flame-resistant - containing water HFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620) NBR ISO 12922

Important information on hydraulic fluids:

For more information and data on the use of other hydraulic fluids please contact us.

There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.).

The flash point of the process and operating medium used must be 40 K over the maximum solenoid surface temperature.

Flame-resistant - containing water:
Maximum pressure differential per control edge 175 bar
Pressure pre-loading at the tank port > 20 % of the pressure differential, otherwise increased cavitation
Life cycle as compared to operation with mineral oil HL, HLP 50 % to 100 %

electrical

Size 6 10
Voltage type   Direct voltage
Maximum current consumption of the amplifier A 2
of the amplifier (impulse current) A 3
Maximum current Output stage A 1.7
Signal part A 0.3
Actuated time 1)   % 100
Maximum coil temperature 2)   °C 150
Protection class according to DIN EN 60529   IP65 (with mating connector mounted and locked)
Converter resolution (command/actual value signals)   bits 10
Power supply   V 24
Supply voltage range   V 19.4 … 35
Earthing (GND)   V 0
Enable input range "A6" V 9 … 35
"F6" V 9 … 35
Command value input UQ "A6" mA 10
Command value input range UP "A6" mA 0 … 10
IQ and IP "F6" mA 4 … 20
Actual value output UQ "A6" V ± 10
Actual value output range UP "A6" mA 0 … 10
IQ and IP "F6" mA 4 … 10
Control voltage   Level as for pin 1
0 V reference potential   For pins 3, 6, 8 and 11 (connected to pin 2 in valve)
Error output   24 V (19.4 V to 35 V), 200 mA maximum load
1) Connect the valve to the supply voltage only when this is required for the functional sequence of the machine.
2) Due to the surface temperatures occurring at solenoid coils, the European standards ISO 13732-1 and ISO 4413 need to be adhered to.

Sensor technology

Overload protection Sensor 100 bar bar 200
Sensor 160 bar bar 320
Sensor 250 bar bar 500
Sensor 400 bar bar 800
Bursting pressure Sensor 100 bar bar 400
Sensor 160 bar bar 640
Sensor 250 bar bar 1000
Sensor 400 bar bar 1600
Characteristic curve deviation % < 0.2
Hysteresis % < 0.1
Repetition accuracy % < 0.05
Long-term drift (1 year) under reference conditions % < 0.2

For applications outside these parameters, please consult us!

Good price online

Products Details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Rexroth Hydraumatic Parts
Created with Pixso. Bosch Rexroth 4WREQ10Q5-75-2X/VBF-24CA60 Direct Operated Proportional Directional Valve

Bosch Rexroth 4WREQ10Q5-75-2X/VBF-24CA60 Direct Operated Proportional Directional Valve

Brand Name: Rexroth
Model Number: 4WREQ10Q5-75-2X/VBF-24CA60 (R901057547)
MOQ: 1
Price: $418
Payment Terms: T/T,
Detail Information
Brand Name:
Rexroth
Model Number:
4WREQ10Q5-75-2X/VBF-24CA60 (R901057547)
Spool Symbol:
Symbol J
Max. Pressure:
350
Electrical Connection Description:
Cable Gland, Threaded Connection 1/2"-14 NPT, With LED
Productgroup ID:
9,10,11,12,13,14
Number Of Ports:
4
Product Typ:
With Solenoid Actuation
Conformity Description:
CE – Low-Voltage Directive 2014/35/EU CSA Approval According To CSA C22.2 No. 139-1982
Size:
6
Electrical Connector:
Cable Gland
Max. Flow:
60
Connection Diagram:
NFPA T3.5.1 R2-2002 D03
Supply Voltage:
110…120 VAC
Type Of Connection:
Subplate Mounting
Seals:
FKM
Number Of Switching Positions 2:
3
Weight:
1.4
Hydraulic Fluid:
HL,HLP,HLPD,HVLP,HVLPD,HETG,HEES,HEPG,HFDU,HFDR
Minimum Order Quantity:
1
Price:
$418
Payment Terms:
T/T,
Supply Ability:
>100
Highlight:

Bosch Rexroth 4WREQ10Q5-75-2X

,

Proportional Directional Valve

,

Bosch Rexroth Valve 4WREQ10Q5-75-2X

Product Description

Bosch Rexroth 4WREQ10Q5-75-2X/VBF-24CA60 (R901057547) Direct Operated Proportional Directional Valve With State-Of-The-Art Integrated Digital Control Electronics Tailored For Precise Pressure

Product Description:

The Bosch Rexroth 4WREQ10Q5-75-2X/VBF-24CA60 (R901057547) is a direct operated proportional directional valve with state-of-the-art integrated digital control electronics tailored for precise pressure, force, and flow control applications. This innovative valve is designed to operate via proportional solenoids featuring a central thread and detachable coil, ensuring ease of maintenance and high responsiveness. The model includes a valve control spool that is position-controlled for accurate operation. The 4WREQ10Q5-75-2X/VBF-24CA60 valve can be equipped with an optional integrated pressure sensor plate or configured for an external pressure sensor, providing flexibility in monitoring and control based on specific application requirements. It supports subplate mounting with porting patterns according to ISO standards, ensuring compatibility with a wide range of systems. The valve's digital integrated control electronics (IACP) facilitate advanced functionalities such as error detection for cable breaks in the pressure sensor or position transducer, undervoltage issues, communication errors, and watchdog timer faults. Additional features include a ramp generator, internal command value profile, enable function for analog/digital inputs, and an error output of 24 V. Designed to communicate via field bus interfaces like CANopen protocol DS 301 or Profibus-DP, the unit allows for quick commissioning through the WINPED commissioning software. Despite its advanced capabilities, users should be aware that internal leakage is inherent to the design of these valves and may increase over their lifecycle; therefore, it's crucial to ensure that the tank line does not run empty. This Bosch Rexroth valve boasts impressive specifications with a size of 10 and a component series X. It can handle a maximum operating pressure of up to 315 bar and facilitates maximum flow rates up to 75 l/min. Its robust construction and versatile design make it suitable for various demanding hydraulic applications where precision control is critical

4WREQ 6 for external pressure sensor

Bosch Rexroth 4WREQ10Q5-75-2X/VBF-24CA60 Direct Operated Proportional Directional Valve 0

 

Features:

Direct operated proportional directional valve with integrated digital control electronics for the pressure, force and flow control (Integrated Axis Controller IAC-P) Completely adjusted unit consisting of valve, pressure sensor(s) (optional), digital control electronics and field bus connection Operation by means of proportional solenoids with central thread and detachable coil Valve control spool, position-controlled Integrated pressure sensor plate (optional) For subplate mounting: Porting pattern according to ISO 4401 Analog interface for command and actual value Design for CAN bus with CANopen protocol DS 408 or Profibus-DP Quick commissioning via PC and WIN-PED 6 commissioning software



 

Technical date :

 

general

Type 4WREQ
Size 6 10
Installation position   any, preferably horizontal
Ambient temperature range °C -20 … +50
Storage temperature range °C -20 … +80
Weight withsandwich plate (3 sensors) kg 3.6 8.5
without sandwich plate kg 2.4 6.5

hydraulic

Size 6 10
Maximum operating pressure   bar 315
Maximum operating pressure Port P (sensor 100 bar) bar 100
Port P (sensor 160 bar) bar 160
Port P (sensor 250 bar) bar 250
Port P (sensor 400 bar) bar 315
Port T (sensor 100 bar) bar 100
Port T (sensor 160 bar) bar 160
Port T (sensor 250 bar) bar 210
Port T (sensor 400 bar) bar 210
Port A (sensor 100 bar) bar 100
Port A (sensor 160 bar) bar 160
Port A (sensor 250 bar) bar 250
Port A (sensor 400 bar) bar 315
Port B (sensor 100 bar) bar 100
Port B (sensor 160 bar) bar 160
Port B (sensor 250 bar) bar 250
Port B (sensor 400 bar) bar 315
Maximum flow   l/min 80 180
Nominal flow   l/min 8
16
32
25
50
75
Hydraulic fluid     see table
Hydraulic fluid temperature range   °C -20 … +70
preferably °C +40 … +50
Viscosity range   mm²/s 20 … 380
preferably mm²/s 30 … 46
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1)   Class 20/18/15 according to ISO 4406 (c)
Hysteresis   % ≤ 0.1
Range of inversion   % ≤ 0.05
Response sensitivity   % ≤ 0.05
Zero shift upon change of Hydraulic fluid temperature %/10 K < 0.15
Operating pressure %/100 bar < 0.1
1) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.
Hydraulic fluid Classification Suitable sealing materials Standards
Mineral oils and related hydrocarbons HL, HLP NBR / FKM DIN 51524
Flame-resistant - containing water HFC (Fuchs HYDROTHERM 46M, Petrofer Ultra Safe 620) NBR ISO 12922

Important information on hydraulic fluids:

For more information and data on the use of other hydraulic fluids please contact us.

There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.).

The flash point of the process and operating medium used must be 40 K over the maximum solenoid surface temperature.

Flame-resistant - containing water:
Maximum pressure differential per control edge 175 bar
Pressure pre-loading at the tank port > 20 % of the pressure differential, otherwise increased cavitation
Life cycle as compared to operation with mineral oil HL, HLP 50 % to 100 %

electrical

Size 6 10
Voltage type   Direct voltage
Maximum current consumption of the amplifier A 2
of the amplifier (impulse current) A 3
Maximum current Output stage A 1.7
Signal part A 0.3
Actuated time 1)   % 100
Maximum coil temperature 2)   °C 150
Protection class according to DIN EN 60529   IP65 (with mating connector mounted and locked)
Converter resolution (command/actual value signals)   bits 10
Power supply   V 24
Supply voltage range   V 19.4 … 35
Earthing (GND)   V 0
Enable input range "A6" V 9 … 35
"F6" V 9 … 35
Command value input UQ "A6" mA 10
Command value input range UP "A6" mA 0 … 10
IQ and IP "F6" mA 4 … 20
Actual value output UQ "A6" V ± 10
Actual value output range UP "A6" mA 0 … 10
IQ and IP "F6" mA 4 … 10
Control voltage   Level as for pin 1
0 V reference potential   For pins 3, 6, 8 and 11 (connected to pin 2 in valve)
Error output   24 V (19.4 V to 35 V), 200 mA maximum load
1) Connect the valve to the supply voltage only when this is required for the functional sequence of the machine.
2) Due to the surface temperatures occurring at solenoid coils, the European standards ISO 13732-1 and ISO 4413 need to be adhered to.

Sensor technology

Overload protection Sensor 100 bar bar 200
Sensor 160 bar bar 320
Sensor 250 bar bar 500
Sensor 400 bar bar 800
Bursting pressure Sensor 100 bar bar 400
Sensor 160 bar bar 640
Sensor 250 bar bar 1000
Sensor 400 bar bar 1600
Characteristic curve deviation % < 0.2
Hysteresis % < 0.1
Repetition accuracy % < 0.05
Long-term drift (1 year) under reference conditions % < 0.2

For applications outside these parameters, please consult us!